Contents
Next:
List of Figures
Up:
OBSERVER'S MANUAL FOR ISOCAM
Previous:
OBSERVER'S MANUAL FOR ISOCAM
Contents
List of Figures
List of Tables
INTRODUCTION
INSTRUMENT DESCRIPTION
OPTICAL DESIGN
THE SW ARRAY
Readout and integration time (SW)
Noise (SW)
Linearity and saturation (SW)
Gain and encoding (SW)
Effect of charged particles (SW)
Transient and memory effects (SW)
Working example:
Flat-field accuracy (SW)
Dark level (SW)
THE LW ARRAY
Readout and integration time (LW)
Noise (LW)
Linearity and saturation (LW)
Gain and encoding (LW)
Effect of charged particles (LW)
Transients and memory effects (LW)
Working example:
Flat-field accuracy (LW)
Dark level (LW)
The internal Calibration Device (ICD)
CAPABILITIES, INSTRUMENT MODES AND AOTS
Photometric imaging
Spectrophotometric imaging
Polarimetric imaging
GENERAL PERFORMANCE OVERVIEW
Observing with the ISOCAM detector arrays
Filters
Circular Variable Filters (CVF)
Polarizers and polarization maps
Dark measurements
Dark measurement as an OPERATION
Flat-field measurements
CLEAN Procedure for LW array
FLASH-MODE for the SW channel
Noise Components
The different components of the SW array noise
The different components of the LW array noise
Time series
Pointed observations
Beam-switching
Micro-scan
Photometric accuracy
The Cookbook
How to use the Cookbook
ISOCAM Software Simulator
CAM01 - GENERAL OBSERVATION
Description of CAM01
Input Parameters of CAM01
The following input parameters are entered only once for an AOT CAM01 (Single pointing or raster):
The following parameters must be entered for each observation within an AOT CAMO1:
for a single pointing observation with CAM01
Guidelines:
Detailed calculation:
for a single pointing observation with CAM01
for a single pointing observation with CAM01
for a raster scan observation with CAM01
Guidelines:
Detailed calculation:
for a raster scan observation with CAM01
for a raster scan observation with CAM01
CAM02
CAM03 - BEAM-SWITCHING
Description of CAM03
Input Parameters of CAM03
The following input parameters are entered only once for an AOT CAM03:
The following parameters must be entered for each observation within an AOT CAM03:
for a beam-switching observation with CAM03
Guidelines:
Detailed calculation:
for a beam-switching observation with CAM03
for a beam-switching observation with CAM03
CAM04 - CVF Spectral Observation
Description of CAM04
Input Parameters of CAM04
The following input parameters are entered only once for an AOT CAM04:
The following parameters must be entered for each observation within an AOT CAMO4:
for a CVF scan observation with CAM04
Guidelines:
Detailed calculation:
for a CVF scan observation with CAM04
for a CVF scan observation with CAM04
Precautions in using CVF'S
Polarization
Polarization observation
Input Parameters of a Polarization Observation
The following input parameters are entered only once for a Polarization observation:
The following parameters must be entered for each polarization observation:
for polarization observation
Guidelines:
Detailed calculation:
for a polarization observation
for a polarization observation
Short description of the ISOCAM performance simulator
Worked examples
Single pointing observations
Micro-scan observation
Beamswitching observation
CVF scan observation
ZODIACAL BACKGROUND
Blocking Of ISOCAM Filters
Data for the CVFs and the filters
Acronyms
Glossary
ISOCAM Observer's Manual - V1.0
Tue Oct 31 12:06:23 MET 1995